logo

details van de producten

Created with Pixso. Huis Created with Pixso. Producten Created with Pixso.
Heliumlek het Testen Materiaal
Created with Pixso.

2000Pa Helium Leak Testing Equipment For Ceramic Component Of Relay 5×10-11pa·m3/s

2000Pa Helium Leak Testing Equipment For Ceramic Component Of Relay 5×10-11pa·m3/s

Merknaam: HongCe
Modelnummer: HJ113
MOQ: 1 reeks
Prijs: Onderhandelbaar
Betalingsvoorwaarden: T/T
Toeleveringsvermogen: 1 reeks per Maand
Gedetailleerde informatie
Plaats van herkomst:
China
Certificering:
Calibration Certificate(cost additional)
Garantie:
12 maanden
Werkstuk:
Ceramische Component van Relais
Vullende druk voor het pak:
2~2.5 kpa
Evacuatiedruk voor het pak:
-2~-3 kpa
Traceursgas:
Helium
Het tarief van de alarmlekkage:
1.44E-4mbar.L/S
Cyclus:
≤2 mins
Testmodus:
Kanonzuiging
Verpakking Details:
Triplex
Markeren:

Ceramic Component Helium Leak Testing Equipment

,

11pa·m3/s Helium Leak Testing Equipment

Productomschrijving

Helium Leak Testing Equipment For Ceramic Component Of Relay 5×10-11pa·m3/S

 

This equipment is used to test the sealing performance of ceramic components of new energy car relay products.

 

Overview of Helium Leak Testing Equipment:

The leak testing equipment for ceramic components is displayed and controlled by touch screen and button switch. Workpieces are placed manually. Two stations are designed, and each station detects four products at the same time. Products with different specifications can be detected by changing the leak detection fixture. When the system detects the leak, the workpiece to be detected is manually placed on the leak detection tool, and the leak detection tool is communicated with the leak detector through the leak detection switching valve. After the workpiece is placed and positioned, the cylinder descends to push the helium nozzle to press the workpiece. Then start the auxiliary pump and start vacuumizing the interior of the workpiece. Then the leak detector continues to take time to clear the background. When the leak detector reaches the background value, the equipment is sprayed with helium.The leak detector judges the leak rate according to the helium gas infiltration.

 

Technical parameters of Helium Leak Testing Equipment:

Min detectable leak rate: 5×10-11pa·m3/s.
Leak rate display range: 1×10-2 -----1×10-11Pa· m3/s
Start time: ≤ 100s
Response time: ≤ 0.3s
Max pressure of leak detector: 2000Pa
Power requirement: AC220V±10%/50Hz
Leakage rate unit: Pa·m3/s, ppm,mbar·l/s,atm.cc/s
Display interface: Large screen 7.0 inch touch screen display, clear and easy to understand operation interface.

 